Hydrophobised Wood Fibre Insulation for Winter and Summer Heat Protection, Airborne Sound Reduction and can be fitted directly over rafters or sub-decks.
About:
A new dual-profile and lighter, compression-strength board, Hofatex TopTherm and Hofafest UD combination panels are for simpler insulation of roofs and enclosure walls. They are especially suited for increasing the thermal insulation and soundproofing of older buildings.
λD= 0.049/0.042 W/(m.K)
Thickness: 60, 80, 100 mm
Dimensions: 580 x 2500 mm
Applications:
- Additional thermal insulation in reconstructed and newly-constructed buildings
- Insulation of sloping roofs above the rafters
- Insulation of solid enclosure walls - below ventilated facades
- External sheathing of wooden frame-constructed buildings
Technical:
Board designation
|
WF-EN 13171-T4-CS(10/Y)20-TR5-WS2,0 |
| Thickness [mm] |
60 |
80 |
100 |
Thermal resistance R D [m².K/W]
|
1.37 |
1.84 |
2.32 |
| Equiv. diffusion thickness s d [m] |
0.30 |
0.40 |
0.50 |
Heat conductivity λD [W/m.K]
|
0.049/0.042 |
Heat conductivity λ [W/m.K]
|
0.050/0.043 |
Density [kg/m³]
|
260/170 |
Thermal capacity c [kJ/kg.K]
|
2100 |
Diffusion resistance factor μ
|
5 |
Edge
|
tongue and groove |
Flammability EN ISO 11925-2
|
Class - E |
| Construction material class |
DIN 4102 B2 |
| Absorption [kg/m2] |
1 |
| Tensile strength [kPa] |
50/7.5 |
| Compression strength [kPa] |
100/70 |
Packing:
Board thickness (mm)
|
60 |
80 |
100 |
Boards per pallet (pcs)
|
36 |
26 |
22 |
| Weight per pallet (kg) |
626 |
581 |
600 |
Sq.m coverage per pallet
|
52.2 |
37.7 |
31.9 |
Storage, handling and laying:
- Store panels in a dry area and lay them down dry
- Protect the edges against damage
- Lay panels with the tongues facing upwards towards the roof ridge and join them as tightly as possible
- To fasten panels to solid walls, use a combination of glue and insulation anchors; for wood sandwich (framework)-constructed buildings, they can be fastened with staples
- Do not run the panels outside of the rafter beam area
- After laying the panels, lath and contra-lath them as soon as possible
|